Probe Accessories
Model 1304 Control Resistor
Model 1305 Control Resistor
Model 1304 control resistors are used with bridges that have a 5 to 1 ratio, such as TSI's 1750 and 1050/1053/1054 anemometers. The Model 1305 control resistors are used with bridges that have a 1 to 1 bridge ratio such as the 1:1 bridge used for high frequency applications of TSI's IFA100 and 1050 anemometers.
Model 10120 Hot Wire/Film Sensor Repair Kit
Includes equipment needed to attach hot wire or cylindrical film sensors designed for gas applications to needle supports. Kit includes soldering iron with spare tips, single-edge razor blades, soldering stand with clip, jeweler’s broach, soft solder (400°F melting point), distilled water, brush, acid flux, and a file. A microscope or magnifier of about 10X to 20X is also recommended.
Model 10121 Hot Film Replacement Sensors
These are high-quality, alumina-coated hot film sensors (cylindrical elements for air only) for field replacement use. They are furnished in quantities of 10 with mounting instructions.
Model 10122 Hot Wire Replacement Sensors
These are high-quality, platinum-coated tungsten hot wire sensors for field replacement use, furnished in quantities of 12 on a card. Each sensor is strung across a slot for ease in positioning and mounting. The ends of the wires are plated to isolate the active sensor region.
Model 10123 Wire for Hot Wire Sensors
This is the same high-quality, platinum-coated tungsten wire used in the Model 10122 but furnished on a spool in a 2-meter length.
Model 1305 Control Resistor
Model 1304 control resistors are used with bridges that have a 5 to 1 ratio, such as TSI's 1750 and 1050/1053/1054 anemometers. The Model 1305 control resistors are used with bridges that have a 1 to 1 bridge ratio such as the 1:1 bridge used for high frequency applications of TSI's IFA100 and 1050 anemometers.
Model 10120 Hot Wire/Film Sensor Repair Kit
Includes equipment needed to attach hot wire or cylindrical film sensors designed for gas applications to needle supports. Kit includes soldering iron with spare tips, single-edge razor blades, soldering stand with clip, jeweler’s broach, soft solder (400°F melting point), distilled water, brush, acid flux, and a file. A microscope or magnifier of about 10X to 20X is also recommended.
Model 10121 Hot Film Replacement Sensors
These are high-quality, alumina-coated hot film sensors (cylindrical elements for air only) for field replacement use. They are furnished in quantities of 10 with mounting instructions.
Model 10122 Hot Wire Replacement Sensors
These are high-quality, platinum-coated tungsten hot wire sensors for field replacement use, furnished in quantities of 12 on a card. Each sensor is strung across a slot for ease in positioning and mounting. The ends of the wires are plated to isolate the active sensor region.
Model 10123 Wire for Hot Wire Sensors
This is the same high-quality, platinum-coated tungsten wire used in the Model 10122 but furnished on a spool in a 2-meter length.
Literature
Accessories