Cylindrical, dual sensor, end flow - Probes

Model 1241 End Flow "X" Probe

Sensors mounted 90° to each other and 45° to probe axis. Ideal for two-component velocity and turbulence measurements while providing minimum flow disturbance. Available in hot wire and hot film versions for gases (up to 150°C) and liquids. 

For Gas Flows For Liquid Flows Probe Supports Optional
1241-T1.5    Wire
1241-20   Film
1241-20W   Film

1155
1156
1154

1157 Adapter
1137 Mounting Blk
1138 Mounting Blk

  
Model 1248A Miniature End Flow "X" Probe

Offers good spatial resolution and minimal flow disturbance in two-dimensional flow measurements. Available in hot wire and hot film versions for gases (up to 150°C) and hot film version for liquids.
For Gas Flows For Liquid Flows Probe Supports Optional
1248A-T1.5   Wire
1248A-10   Film

1248A-10W   Film
1155
1156
1154
1157 Adapter
1137 Mounting Blk
1138 Mounting Blk

 
Model 1244 End Flow Parallel Sensor Probe

 Dual sensors mounted parallel and closely spaced are used for spatial correlation measurements or simultaneous measurement of velocity and temperature. Available in hot wire and hot film versions for gases (up to 150°C) and hot film version for liquids.

For Gas Flows

For Liquid Flows

Probe Supports

Optional

1244-T1.5

  Wire

1244-20

  Film


1244-20W

  Film

1155

1156

1154

1157 Adapter

1137 Mounting Blk

1138 Mounting Blk


Accessories

Single-channel SMARTTUNE Constant Temperature Anemometer

  • SMARTTUNE automatic bridge optimization technology
  • High frequency response with no tuning
  • Built-in signal conditioner and thermocouple circuits
  • Fully computer-controlled
  • Ultra-low-noise circuits
  • Optional constant current anemometer
  • Optional integrated calibration system
  • Special 1:1 bridge for high frequency response
More Information

Single-channel SMARTTUNE Constant Temperature Anemometer - IFA300

  • SMARTTUNE automatic bridge optimization technology
  • High frequency response with no tuning
  • Built-in signal conditioner and thermocouple circuits
  • Fully computer-controlled
  • Ultra-low-noise circuits
  • Optional constant current anemometer
  • Optional integrated calibration system
  • Special 1:1 bridge for high frequency response

Temperature Module with Signal Conditioner - 183145

Module supplies the sensing current and signal conditioning needed to use a fine wire sensor as a resistance thermometer. Plugs into a standard TSI IFA300 research thermal anemometer.

Add-on SMARTTUNE CTA Module - 183150

SMARTTUNE™ CTA Module w/Signal Conditioner is the plug-in module for additional channels of anemometry

      Make Enquiry

      • Kenelec Scientific Headquarters
        23 Redland Drive, Mitcham, VIC, Australia 3132
        Ph: +61 3 9873 1022
        Fax: +61 3 9873 0200
      • National Freecall No.
        1300 73 2233
      • Kenelec Scientific NSW
        Building 5, 49 Frenchs Forest Road, Frenchs Forest NSW, Australia 2086
        Ph: +61 2 8977 4017
        Fax: +61 2 8977 4000