Cylindrical, single sensor, end flow - Probes
Model 1201 General Purpose Probe
Inexpensive, disposable probe for single component measurements up to 60°C. Sold in multiples of six probes. Available in hot film version for gases.
| For Gas Flows | For Liquid Flows | Probe Supports | Optional | ||||
|
1150 |
1158 Shield 1139 Shield 1132 Shield 1137 Mounting Blk 1138 Mounting Blk |
Model 1210 General Purpose Probe
Commonly used probe for single component measurements. Available in hot wire and hot film versions for gases (up to 150°C) and hot film versions for liquids.
| For Gas Flows | For Liquid Flows | Probe Supports | Optional | ||||||||
|
|
1150 1151 1159 |
1158 Shield 1139 Shield 1132 Shield 1137 Mounting Blk 1138 Mounting Blk |
Model 1220 High Temperature Straight Probe
Commonly used probe for single component measurements at elevated fluid temperatures up to 300°C. Available in hot wire and hot film versions for use in gas flows.
| For Gas Flows | For Liquid Flows | Probe Supports | Optional | ||
|
1160 | 1158 Shield 1139 Shield 1132 Shield 1137 Mounting Blk 1138 Mounting Blk |
Model 1260A Miniature Straight Probe
Ideal for single component measurements in small flow sections, narrow spaces, and other small test sections. Available in hot wire and hot film versions for gases (up to 150 °C) and hot film version for liquids.
| For Gas Flows | For Liquid Flows | Probe Supports | Optional | ||||
|
|
1150 1151 1159 |
1132 Shield 1133 Shield 1137 Mounting Blk 1138 Mounting Blk |
Model 1214 Streamlined Probe
Support needles and probe body are wedge-shaped to minimize flow disturbance. Recommended for clean, filtered gas flows (up to 150 °C) at supersonic velocities. Available in hot wire and hot film versions for use in gas flows.
| For Gas Flows | For Liquid Flows | Probe Supports | Optional | ||||
|
1150 1151 |
1158 Shield 1139 Shield 1132 Shield 1137 Mounting Blk 1138 Mounting Blk |
Model 1213 Sensor 45° to Probe
Slant sensor orientation permits measurement of up to three mean velocity components with a single sensor by rotating the probe about its axis. Available in hot wire and hot film versions for gases (up to 150 °C) and hot film version for liquids.
|
For Gas Flows |
For Liquid Flows |
Probe Supports |
Optional |
||||
|
|
1150 1151 1159 |
1158 Shield 1139 Shield 1132 Shield 1137 Mounting Blk 1138 Mounting Blk |
Literature
Accessories

Single-channel SMARTTUNE Constant Temperature Anemometer
- SMARTTUNE automatic bridge optimization technology
- High frequency response with no tuning
- Built-in signal conditioner and thermocouple circuits
- Fully computer-controlled
- Ultra-low-noise circuits
- Optional constant current anemometer
- Optional integrated calibration system
- Special 1:1 bridge for high frequency response
