PLIF - PIV System

The TSI Planar Laser-Induced Fluorescence (PLIF) system provides non-intrusive, global measurements of scalar quantities such as temperature, concentration, pH, and species. Fluorescence measurements are routinely applied in research areas such as combustion, mixing, spray analysis, contaminant mass transfer, and plasma physics. The TSI PLIF system is engineered on a flexible platform built for expansion, and advanced analysis algorithms are incorporated into a user-friendly environment for simple, accurate quantification of the property of interest based on the measured fluorescence intensity field. The PLIF system can be seamlessly coupled with a TSI PIV system for simultaneous global velocity measurements, thus providing information on heat and mass fluxes.

Features & Benefits

  • Provides global measurements of scalar quantities such as concentration, temperature, pH, and species
  • Advanced analysis algorithms to account for camera noise, background signals, spatial variations in laser sheet intensity, temporal variations in laser pulse energy
  • User-programmable image analysis schemes for maximum experimental flexibility
  • Full range of camera support, including all TSI intensified and un-intensified cameras
  • Seamless integration with TSI PIV systems for simultaneous global velocity measurements
  • Excitation wavelength flexibility from UV into IR

Applications

  • Spray analysis
  • Mixing studies
  • Contaminant mass transfer
  • Combustion diagnostics

Included Items

  • PLIF laser (specific model depends upon species being measured)
  • CCD camera (specific model depends upon application; includes camera lens, all interface cables, camera frame grabber)
  • INSIGHT™ 3G-LIF Data Acquisition, Analysis and Display Software Package
  • Light sheet optics (and optional Laser Light Arm)
  • Optical filter(s) (specific PLIF filter depends on species being measured)
  • LASERPULSE™ Synchronizer (Model 610035)
  • All associated manuals

Accessories

PIV System Global Sizing Velocimeter (GSV)

  • Single camera operation simplifies measurements and improves accuracy
  • Simultaneous measurements of droplet Size and Velocity
  • Unique hardware configuration for higher accuracy, even in high-concentration or varying droplet refractive index situations
  • Inhomogeneous, reacting, and even absorbing droplets can be measured with no additional corrections required
  • Patented processing algorithms have been theoretically and experimentally validated
  • Simple system setup and turn-key operation using stored hardware parameters
  • Simple upgrade from PIV Systems to perform GSV measurements
More Information

Filters

  • Full range of transmission wavelengths
  • Long wave pass, short wave pass, and band pass filters
  • Built in threaded mounts for direct attachment to camera lens

Remote Focus Mechanism - 640050/1-R

  • Precise remote control of the camera lens focusing to the particle images
  • Coarse and fine controls with stepper motor
  • Applicable for all Nikon F-mount camera lenses (or equivalent)
  • Applicable for all the TSI POWERVIEW Plus and PIVCAM series of PIV/PLIF cameras
  • Applicable for all POWERVIEW series of high frame rate PIV cameras
  • Upgradeable to aperture control for camera lenses

Six-jet Atomizer - 9306

  • External control for selecting up to six atomizer jets
  • External control of dilution air flow rate to adjust output concentrations and dry solid particles
  • Generates and expels particles into pressurized
  • Generation of polydisperse aerosols in high concentrations environments 

Oil Droplet Generator - 9307

The Oil Droplet Generator (TSI Model 9307) is used to produce large quantities of oil droplets for seeding flows when making PIV or LDV measurements. The large droplet output is especially useful for seeding high-speed flows.

Fog Generator - 9308

  • High capacity
  • Quick warmup time
  • Seeding oil is non-toxic
  • Remote control included

PIV System Global Sizing Velocimeter (GSV) - GSV

  • Single camera operation simplifies measurements and improves accuracy
  • Simultaneous measurements of droplet Size and Velocity
  • Unique hardware configuration for higher accuracy, even in high-concentration or varying droplet refractive index situations
  • Inhomogeneous, reacting, and even absorbing droplets can be measured with no additional corrections required
  • Patented processing algorithms have been theoretically and experimentally validated
  • Simple system setup and turn-key operation using stored hardware parameters
  • Simple upgrade from PIV Systems to perform GSV measurements

Mount Kits for PIV

  • Quick setup time
  • Long term stability
  • Ease of use
  • Simple adjustments
  • Rugged but precise
  • Rotates to any angle

Rails for PIV - Rails for PIV

TSI Rails provide the flexibility in a sturdy support system needed for any PIV system. Various lengths are available, to customise the system to the cameras and light sheet optics used.

Seeding Particles

  • Full range of particle materials
  • Full range of particle sizes
  • Fluorescent particles for micro PIV experiments

POWERVIEW Plus Cameras - 2MP

  • Very high spatial resolution, up to 11 million pixels
  • Low noise characteristics
  • Frame-straddling capability
  • Up to 32 frames per second framing rate

POWERVIEW Cameras - HS-200

  • High speed image capture for PIV and PLIF applications
  • Frame rate from 200 to 500 fps with Camera Link output
  • Protective mask prevents fatal damage to the CCD array by laser light
  • 12-bit intensity dynamic range
  • Single and dual (stereo) camera configurations
  • Option to be used with the HyperStreaming™ Image Transfer System

Traverse Accessories for PIV - Traverse Accessories for PIV

Traverse accessories help the user get the most productivity out of their TSI traverse while enhancing operating safety. Casters permit the traverse to be easily moved from place to place, increasing the versatility of the PIV system. Foundation brackets rigidly attach the base frame to the floor to prevent tipping when floor is uneven, in earthquake-prone areas, or when the traverse is unevenly loaded.

Synchronizer - 610034

  • External trigger option for phase-locked velocity measurements
  • Automates control of laser pulses, cameras, and timing to external signals

  