Module supplies the sensing current and signal conditioning needed to use a fine wire sensor as a resistance thermometer. Plugs into a standard TSI IFA300 research thermal anemometer.
|
|
Most TSI Thermal Anemometry probes are built with a plug-in connector. Thus, they require a probe support which serves to support the probe and provide an electrical connection to the anemometer. TSI probe supports come in a wide variety of configurations and lengths, for both single- and dual-sensor probes (standard three-sensor probes are designed with a probe support built-in), and for either gas or liquid flow applications. Right angle adapters, available for both single- and dual-sensor probes, allow probe mounting in an end flow orientation, even when the probe support is mounted in a cross flow arrangement. Totally immersible probe supports are also available for liquid flow applications.
|
|
Model 1304 control resistors are used with bridges that have a 5 to 1 ratio, such as TSI's 1750 and 1050/1053/1054 anemometers. The Model 1305 control resistors are used with bridges that have a 1 to 1 bridge ratio such as the 1:1 bridge used for high frequency applications of TSI's IFA100 and 1050 anemometers.
|
|
Completely protects sensor while providing opening for cross flow measurements. Probe can be extended beyond end for unobstructed measurements. Fits Model 1150 probe supports.
|
|
Measures temperature of measurement environment. Thermocouple Type-T copper-constantan.
|
- Works with one-, two-, or three-sensor probes
- Probe mounts for yaw/pitch calibration
- Works with any thermal anemometer
- Accepts a wide range of thermal anemometry probes and probe supports
|
- Works with one-, two-, or three-sensor probes
- Probe mounts for yaw/pitch calibration
- Works with any thermal anemometer
- Accepts a wide range of thermal anemometry probes and probe supports
- Choice of three pressure transducers
|
- Complete automation of calibration data acquisition
- Works with one-, two-, or three-sensor probes
- Probe mounts for yaw/pitch calibration
- Integrates with IFA 300 and THERMALPRO software
|
|
Provides sealing fitting for probe traversing and for mounting probe supports to the wall of a test section.
|
SMARTTUNE™ CTA Module w/Signal Conditioner is the plug-in module for additional channels of anemometry
|
- SMARTTUNE automatic bridge optimization technology
- High frequency response with no tuning
- Built-in signal conditioner and thermocouple circuits
- Fully computer-controlled
- Ultra-low-noise circuits
- Optional constant current anemometer
- Optional integrated calibration system
- Special 1:1 bridge for high frequency response
|
|
Sensors mounted 90° to each other and in a plane 90° to probe axis. For measuring two velocity components, correlations, and flow vectors in two-dimensional flows. Available in hot wire and hot film versions for gases (up to 150°C) and hot film version for liquids.
|
|
Sensors mounted 90° to each other and 45° to probe axis. Ideal for two-component velocity and turbulence measurements while providing minimum flow disturbance. Available in hot wire and hot film versions for gases (up to 150°C) and liquids.
|
|
Single sensor probes are used to measure one component of velocity. The sensor needles are designed to have minimum probe interference to measure cross flows.These probes are available in different sizes and configurations.
|
|
Inexpensive, disposable probe for single component measurements up to 60°C. Sold in multiples of six probes. Available in hot film version for gases.
|
|
Standard probe for three-component measurements. Sensor orientation designed to minimize sampling volume and minimize flow disturbance. For velocity and turbulence measurements to 150°C. Available in hot film versions for gases.
|
|
Standard probe for three-component measurements. Sensors oriented to minimize sampling volume and flow disturbance. For velocity and turbulence measurements to 150°C. Available in hot film version for gases.
|
|
Most TSI Thermal Anemometry probes are built with a plug-in connector. Thus, they require a probe support which serves to support the probe and provide an electrical connection to the anemometer. TSI probe supports come in a wide variety of configurations and lengths, for both single- and dual-sensor probes (standard three-sensor probes are designed with a probe support built-in), and for either gas or liquid flows. Right angle adapters, available for both single- and dual-sensor probes, allow probe mounting in an end flow orientation, even when the probe support is mounted in a cross flow arrangement. Totally immersible probe supports are also available for liquid applications.
|
Computer-controlled traverses precisely locate and move a thermal anemometer probe as part of a thermal anemometer system.
|
- Comprehensive data acquisition and analysis for thermal anemometry applications
- Microsoft Windows XP-based operation
- Provides results in fluid mechanics terms
- Analyzes data from one-, two-, or three-sensor probes
- Controls the TSI Automated Calibrator
- Controls the TSI family of probe traverse systems
- Accurate calibration of sensors including yaw and pitch calibrations
|