Standard Features
- 0.1um to 10um particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 400mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable and fixed air monitoring applications
- Ethernet, 4-20mA, 0-5V and USB communications
- Capable of collecting a 37mm filter sample for analysis
Enhanced Features
- Measures PM1, PM2.5, PM4 & PM10 dust fractions (one at a time, user selectable)
- Optional auto zero module provides 1ug/m3 stability at all times
- Optional outdoor enclosures, heated inlets, tripods, telemetry packs, solar panels and more
- Countless other options and accessories for portable, tripod based and fixed air monitoring
Australasia's biggest selling real-time laser based dust monitor. As used by thousands of leading organizations throughout Australasia. Exclusively imported by Kenelec Scientific and distributed throughout Australasia
|
Standard Features
- 0.1um to 10um particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 150mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable air monitoring applications
- USB interface and software
Enhanced Features
- Measures PM1, PM2.5, PM4 & PM10 dust fractions (one at a time, user selectable)
- Countless other options and accessories for portable, tripod based and fixed air monitoring
An ideal companion for the indoor or outdoor air monitoring professional, occupational hygienest or aerosol researcher. This portable handheld model offers most of the features of the other DustTrak models at a great entry level price. Exclusively imported by Kenelec Scientific and distributed throughout Australasia
|
Standard Features
- 0.1um to 15um extended particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 150mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable and fixed air monitoring applications
- Ethernet, 4-20mA, 0-5V and USB communications
- Capable of collecting a 37mm filter sample for analysis
Enhanced Features
- Simultaneously measures all 5 PM fractions (PM1, PM2.5, PM4, PM10 & Total PM)
- Optional auto zero module provides 1ug/m3 stability at all times
- Optional outdoor enclosures, heated inlets, tripods, telemetry packs, solar panels and more
- Countless other options and accessories for portable, tripod based and fixed air monitoring
Australasia's biggest selling multi-channel real-time laser based dust monitor. As used by the Australian EPA, health authorities and countless other leading organizations. No other instrument in its class matches the features and performance of the popular TSI 8533 DRX dust monitor.
|
Standard Features
- 0.1um to 15um extended particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 150mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable air monitoring applications
- USB interface and software
Enhanced Features
- Simultaneously measures all 5 PM fractions (PM1, PM2.5, PM4, PM10 & Total PM)
- Countless other options and accessories for portable air monitoring
An extremely popular and veratile monitor used throughout Australia and the world for portable multi-channel air monitoring applications. Packed full of features the 8534 is the ideal companion for the dust monitoring professional.
|
- 0.1 μm to 10 μm particle size range
- 1 ug/m3 to 20 mg/m3 concentration range
- Measures all the popular PM fractions, PM1, PM2.5, PM4 and PM10
- Provides real-time laser based results
- Easy to use, rugged and reliable
- 33,000 point data logging with software
- Ideal for indoor air, environmental & OH&S work
- Built-in pump, ready to use, with AA batteries
- Features smart battery technology
- Simply clips on the belt of any worker and provides valuable time, date and event data that normal filter samplers and pumps cannot do
- Fully calibrated with a 2 year warranty
|
- 0.1 μm to 10 μm particle size range
- 1 ug/m3 to 20 mg/m3 concentration range
- Measures all the popular PM fractions, PM1,PM2.5, PM4 and PM10
- Provides real-time laser based results
- Easy to use, rugged and reliable
- 33,000 point data logging with software
- Ideal for indoor air, environmental & OH&S work
- Built-in pump, re-chargeable 1650mA battery
- Features smart battery technology
- Simply clips on the belt of any worker and provides valuable time, date and event data that normal filter samplers and pumps cannot do
- Fully calibrated with a 2 year warranty
|
- 0.1 μm to 10 μm particle size range
- 1 ug/m3 to 20 mg/m3 concentration range
- Measures all the popular PM fractions, PM1, PM2.5, PM4 and PM10
- Provides real-time laser based results
- Easy to use, rugged and reliable
- 33,000 point data logging with software
- Ideal for indoor air, environmental & OH&S work
- Built-in pump, re-chargeable 2700mA battery
- Features smart battery technology
- Simply clips on the belt of any worker and provides valuable time, date and event data that normal filter samplers and pumps cannot do