- 0.1 μm to 10 μm particle size range
- 1 ug/m3 to 20 mg/m3 concentration range
- 33,000 point data logging with software
- Ideal for indoor air, environmental & OH&S work
- Built-in pump, battery operated, ready to use
- Fully calibrated with a 2 year warranty
|
• Measures all 3 respirable, thoracic and inhalable particle size fractions simultaneously • Ideal for the OH&S and indoor air professional • Collect air samples on PVC or fibreglass filters for microscopic or gravimetric analysis • Requires a 3.11 lpm vacuum pump
|
- The AE51 is a handheld instrument that detects and quantifies the presence of aerosol black carbon
- Weighing just 8.8 ounces (250 g)
- The AE51 is the smallest and lowest cost BC monitor in the world
- Real-time, high-resolution, wide dynamic range and data logging performance
- 0-1 mg BC/m3 range
- Data storage space for up to a month of measurements
|
Standard Features
- 0.1um to 10um particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 150mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable and fixed air monitoring applications
- Ethernet, 4-20mA, 0-5V and USB communications
- Capable of collecting a 37mm filter sample for analysis
Enhanced Features
- Measures PM1, PM2.5, PM4 & PM10 dust fractions (one at a time, user selectable)
- Optional auto zero module provides 1ug/m3 stability at all times
- Optional outdoor enclosures, heated inlets, tripods, telemetry packs, solar panels and more
- Countless other options and accessories for portable, tripod based and fixed air monitoring
Australasia's biggest selling real-time laser based dust monitor. As used by thousands of leading organizations throughout Australasia. Exclusively imported by Kenelec Scientific and distributed throughout Australasia
|
Standard Features
- 0.1um to 10um particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 400mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable and fixed air monitoring applications
- Ethernet, 4-20mA, 0-5V and USB communications
- Capable of collecting a 37mm filter sample for analysis
Enhanced Features
- Measures PM1, PM2.5, PM4 & PM10 dust fractions (one at a time, user selectable)
- Optional auto zero module provides 1ug/m3 stability at all times
- Optional outdoor enclosures, heated inlets, tripods, telemetry packs, solar panels and more
- Countless other options and accessories for portable, tripod based and fixed air monitoring
With all the features of the popular 8530 model, the 8531 is the ultimate real-time dust monitoring instrument for ultra high concentrations of dust or aerosol. Exclusively imported by Kenelec Scientific and distributed throughout Australasia
|
Standard Features
- 0.1um to 10um particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 150mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable air monitoring applications
- USB interface and software
Enhanced Features
- Measures PM1, PM2.5, PM4 & PM10 dust fractions (one at a time, user selectable)
- Countless other options and accessories for portable, tripod based and fixed air monitoring
An ideal companion for the indoor or outdoor air monitoring professional, occupational hygienest or aerosol researcher. This portable handheld model offers most of the features of the other DustTrak models at a great entry level price. Exclusively imported by Kenelec Scientific and distributed throughout Australasia
|
Standard Features
- 0.1um to 15um extended particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 150mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable and fixed air monitoring applications
- Ethernet, 4-20mA, 0-5V and USB communications
- Capable of collecting a 37mm filter sample for analysis
Enhanced Features
- Simultaneously measures all 5 PM fractions (PM1, PM2.5, PM4, PM10 & Total PM)
- Optional auto zero module provides 1ug/m3 stability at all times
- Optional outdoor enclosures, heated inlets, tripods, telemetry packs, solar panels and more
- Countless other options and accessories for portable, tripod based and fixed air monitoring
Australasia's biggest selling multi-channel real-time laser based dust monitor. As used by the Australian EPA, health authorities and countless other leading organizations. No other instrument in its class matches the features and performance of the popular TSI 8533 DRX dust monitor.
|
Standard Features
- 0.1um to 15um extended particle size range
- 0.1um to 500um particle sensitivity range
- 0.001 to 150mg/m3 concentration range
- Impressive +/- 0.002mg/m3 zero stability
- 0.001 mg/m3 resolution
- Built-in 3 lpm pump (variable from 1.4 to 3 lpm)
- Built-in 60,000 point data logger (5MB), one sample per minute for 45 days
- Uses the latest 90 degree light scattering & long life laser diode technologies
- Designed for portable air monitoring applications
- USB interface and software
Enhanced Features
- Simultaneously measures all 5 PM fractions (PM1, PM2.5, PM4, PM10 & Total PM)
- Countless other options and accessories for portable air monitoring
An extremely popular and veratile monitor used throughout Australia and the world for portable multi-channel air monitoring applications. Packed full of features the 8534 is the ideal companion for the dust monitoring professional.
|