High Volume Samplers

Flow Choice High Volume Samplers

For compliance monitoring and/or TSP measurements, Kenelec Scientific offers a range of quality, high volume samplers at competitive prices. The Flow Choice series of High Volume Air Samplers utilises a precise and versatile venturi sampling system featuring electronic flow control. They also meet the most recent international methods for atmospheric particulate matter measurement. Available configurations include: Total Suspended Particulates (TSP), PM10 and PM2.5. Each instrument includes a speed controlled brushless blower for accurate, quiet operation and 2 filter holders for easy exchange in the field.

An integrated real time clock, wide graphic display and dedicated keypad allows for user friendly sample programming. The user can select from automatic 3 and 6 day runs or can simply create their own program selectable from 1 minute to 168 hours. The microprocessor controlled system allows for measurement of ambient and orifice flow temperatures, ambient and venturi pressures. It allows true mass or volumetric flow standardized to a user selectable reference temperature.

Measured parameters are logged every five seconds and recorded as five minute averages for the 24 hour run period. Run time, averages flow and standard deviation are just some of the obtainable results from the Flow Choice allowing the user to validate the sample run. Data is accessible on the display and can be downloaded to a PC via RS232 or Modem (optional).

SPACE
  • TSP, PM10 or PM2.5 configurations
  • Automatic 3 and 6 day runs
  • User selectable programs
  • Fully complies with Australian standards
  • Remote control via modem (optional)
  • Brushless blower
  • Accurate flow and quiet operation
  • Flow rate, total volume, temperature and pressure are logged and data is available for download to your PC
  • Easy to setup and operate
  • The only devices for TSP measurements
SPA SPA

Flow Choice for PM2.5 Monitoring

Flow Choice for PM10 Monitoring

Flow Choice for TSP Monitoring

  • Includes a PM2.5 inlet head, 2 filter holders and a 10A power socket

  • Ideal for compliance monitoring

  • Measures both standard and actual flow rate, standard and actual total volume, ambient temperature, ambient pressure and pressure drop on the filter

  • Constructed from anodized aluminium, with other material options available

  • Flow range 1000 to 1400 litres per minute

  • Flow stability of +/- 1% of the set flow rate

  • 0 to 50 degree C operating range

  • Weighs 42 Kg, plus inlet head

  • Detachable base. Inlet head easily attached on site

  • Brushless blower which is speed controlled to limit noise and provide extremely accurate flow control

  • 240VAC, 10 Amp power requirements

  • 30 sample point data memory

  • RS232 interface

  • Large LCD graphic display with dedicated keypad and real-time clock

  • 1 minute to 168 hour sample time programming

  • Optional calibration kit

  • Many other advanced features

  • Includes a PM10 inlet head, 2 filter holders and a 10A power socket

  • Ideal for compliance monitoring

  • Measures both standard and actual flow rate, standard and actual total volume, ambient temperature, ambient pressure and pressure drop on the filter

  • Constructed from anodized aluminium, with other material options available

  • Flow range 1000 to 1400 litres per minute

  • Flow stability of +/- 1% of the set flow rate

  • 0 to 50 degree C operating range

  • Weighs 42 Kg, plus inlet head

  • Detachable base. Inlet head easily attached on site

  • Brushless blower which is speed controlled to limit noise and provide extremely accurate flow control

  • 240VAC, 10 Amp power requirements

  • 30 sample point data memory

  • RS232 interface

  • Large LCD graphic display with dedicated keypad and real-time clock

  • 1 minute to 168 hour sample time programming

  • Optional calibration kit

  • Many other advanced features

  • Includes a TSP inlet head, 2 filter holders and a 10A power socket

  • Ideal for compliance monitoring

  • Measures both standard and actual flow rate, standard and actual total volume, ambient temperature, ambient pressure and pressure drop on the filter

  • Constructed from anodized aluminium, with other material options available

  • Flow range 1000 to 1400 litres per minute

  • Flow stability of +/- 1% of the set flow rate

  • 0 to 50 degree C operating range

  • Weighs 42 Kg, plus inlet head

  • Detachable base. Inlet head easily attached on site

  • Brushless blower which is speed controlled to limit noise and provide extremely accurate flow control

  • 240VAC, 10 Amp power requirements

  • 30 sample point data memory

  • RS232 interface

  • Large LCD graphic display with dedicated keypad and real-time clock

  • 1 minute to 168 hour sample time programming

  • Optional calibration kit

  • Many other advanced features

  • Kenelec Scientific Headquarters
    23 Redland Drive, Mitcham, VIC, Australia 3132
    Ph: +61 3 9873 1022
    Fax: +61 3 9873 0200
  • National Freecall No.
    1300 73 2233
  • Kenelec Scientific NSW
    Building 5, 49 Frenchs Forest Road, Frenchs Forest NSW, Australia 2086
    Ph: +61 2 8977 4017
    Fax: +61 2 8977 4000