Listed below are just some of the local calibration services that are available to our clients using anemometers, air capture hoods, vane and hotwire anemometers, air and liquid particle counters, indoor and outdoor air quality monitors and related products. While we are obviously very dedicated to our own product brands, we also offer verification, calibration and in some cases service facilities for other brand instrumentation. For further information on our range of service and calibration capabilities, please feel free to contact Mark Williams in our calibration laboratory.
Flow Measuring Hoods
  • The only dedicated, professional hood calibration system of its type in Australasia
  • Full calibration and multi-point adjustment of flow measuring hoods from 0-1000 l/s
  • Calibrations are done in both supply and return modes with +/-2% accuracy
  • Incorporates multiple, high resolution NATA certified pressure transducers
  • Fully temperature and barometric pressure compensated - NATA certified
  • Manned by factory trained engineering staff with over 34 years experience
  • Fully computer controlled, firmware and software validated facility
  • One of only 3 such advanced flow hood calibration systems world-wide
  • The most accurate system of its type in the Southern Hemisphere
  • Flow verified by a 3 dimensional phase doppler flow and particle analysis system
  • Control frequency and voltage accuracy of 0.00035%
  • Located in our Melbourne head office near our technical services department
  • Prompt turnaround of air capture hoods, usually within 48 hours (nationally)
Hotwire Anemometers
  • Full calibration of multi-point adjustment of anemometers from 0 - 50m/s
  • Extreme accuracy of down to +/- 1% of reading - NATA Certified
  • Specifically dedicated for the precision calibration of hotwire anemometers
  • Incorporates the use of a TSI laser verified certification system
  • The widest velocity calibration range for anemometers in Australia
  • Operated by factory trained, professional engineering staff
Temperature, Humidity, Dewpoint & Pressure Instruments
  • Dewpoint calibration & adjustments from -10 - +85 deg C with extreme accuracy
  • Temperature calibrations from 5 - 95 deg C with 0.03% of reading accuracy
  • Humidity calibrations from 0.5% - 99% +/- 0.5 % at 40% RH +/- 1.25% at 95% RH
  • Pressure calibrations from 0 - 35kpa with 0.025% of reading accuracy
  • All of the above calibration systems are fully NATA Certified
  • Operated by factory trained, professional engineering staff
Vane Anemometers
  • Full calibration & multipoint adjustments from 0.25 - 30m/s
  • Accuracy is 1% of reading or +/- 0.015m/s - NATA Certified
  • Incoporates the same advanced flow rig used for hot wire anemometers
  • Fast 48 hour turn around time of TSI brand vane anemometers
  • Full verification and sometimes adjustment of other brand anemometers
  • Spare parts & repairs for all TSI and some other brand anemometers
Water & Liquid Particle Counters - (Now also Malvern ASL100 & Related Models)
  • Full multi-point calibration and adjustment of liquid counters & sizers
  • 2um - 30um particle size calibration range (other ranges available)
  • Fully traceable to NIST / NATA standards
  • Spare parts and full service facilities are available
  • Factory trained optical / electronic technicians with over 25 years experience
  • Fast turn around of PMS, Chemtrac and related instrumentation
Air Particle Counters & Sizers
  • Full multi-point calibration and adjustment of air counters from 0.3um - 10um
  • Calibrated to NATA standards for use in pharmaceutical and other industries
  • Fast turn around time, with loan and rental units available if required
  • Spare parts, laser diodes, optics and electronics may all be replaced locally
  • Performed by experienced optical / electronic engineering staff
TSI Dust Monitors / Aerosol Photometers
  • Full calibration, testing, adjustment and cleaning to NIST traceable standards
  • Accuracy of 0.001mg/m3 using the latest optical calibration techniques
  • Replacement of laser diodes, electronics and other optical components
  • Calibration performed using NIST traceable ISO certified test dust
  • Fast turn around time, with rental and loan units available in the meantime
  • Calibrated using factory trained optical / electronic engineering staff
Indoor Air Quality & Gas Monitoring Instruments
  • Dewpoint calibration & adjustments from -10 - +85 deg C with extreme accuracy
  • Temperature calibrations from 5 - 95 deg C with 0.03% of reading accuracy
  • Humidity calibrations from 0% - 99% with up to 1% accuracy
  • CO2 calibrations from 0 to 15,000ppm
  • CO calibrations from 0 to 500ppm
  • Other gases also available - All NATA Certified
Laserspeed Length & Speed Measuring Systems
  • Calibration of non-contact length measuring devices
  • Calibration of non-contact speed measuring devices from 0-3500 m/m
  • Accuracy levels to within + - 0.01%
  • Calibrated to NIST traceable standards using the latest technologies
  • Calibrated using factory trained engineering staff
  • Calibration of ovality, flaw, diameter, width and thickness gauges
Why Send Your Instruments To Kenelec Scientific
Established in 1962, Kenelec Scientific has close to 40 years experience in the field of 
optical / electronic instrumentation. Employing factory trained engineering staff and working
with the world's leading manufacturers of air and liquid particle instrumentation, we are able
to offer a wide range of professional calibration services at very competitive prices. In most
cases we are also able to have your calibration finished within  48 hours, depending on
the workload within our calibration facility. We have experience and technology to provide
our clients with the very best technical support available throughout Australasia. We also
work closely with numerous leading universities, research facilities and organisations to
ensure the best possible support network is available to our clients.

Kenelec Scientific Pty Ltd